|
公司基本資料信息
|
MS-15W series MINI single switching power supply
Features:
·Universal AC inputrange
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model |
MS-15-5 |
MS-15-12 |
MS-15-15 |
MS-15-24 |
|
output |
DC voltage |
5V |
12V |
15V |
24V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
|
Rated current |
3A |
1.3A |
1A |
0.7A |
|
Current range |
0~3A |
0~1.3A |
0~1A |
0~0.7A |
|
Rated power |
15W |
15.6W |
15W |
16.8W |
|
Ripple&noise |
80mvp-p |
120mvp-p |
120mvp-p |
150mvp-p |
|
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
|
input |
Voltage range |
90~264VAC,235~373VDC |
|||
frequency |
47~63HZ |
||||
AC current |
0.25A/230VAC |
||||
efficiency |
76% |
78% |
78% |
80% |
|
Inrush current |
Cold start current 30A/230VAC |
||||
Leakage current |
< 0.5mA/240VAC |
||||
protection |
overload |
Rated output power115%~150% start over load protection |
|||
protection type :part layer type current limit,auto-recovery after fault condition is removed |
|||||
----- |
----- |
||||
----- |
|||||
environment |
Working temp,humidity |
-10℃~+60℃,20%~90%RH |
|||
Storage temp,humidity |
-20℃~+85℃,10%~95%RH non-condensing |
||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
||||
Fit standard |
Safety standard |
Compliance toUL1012 |
|||
EMC standard |
Compliance to EN55022,CLASSA |
||||
others |
Dimension |
84*58*30mm (L*W*H) |
|||
MTBF |
550K hrs min. MIL-HDBK-217F(25℃) |
||||
Weight/packing |
0.15kg/80pcs/13kg/0.024m³/0.87CUFT |
||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |